ClustalW
序列比对
The Sequence Alignment tool is an online bioinformatics tool based on the MAFFT and ClustalW multiple sequence alignment algorithms. It supports pairwise and multiple alignments of nucleotide or amino acid sequences, with database sequence retrieval and custom input. Visual results show conserved positions, sequence differences and UTR/CDS annotations from known sources to support studies of gene function and evolutionary relationships.
Overview

Sequence alignment is a key bioinformatics procedure used to study gene function, evolutionary relationships and disease-associated sequences. This tool uses the ClustalW global alignment algorithm for pairwise and multiple alignments of nucleotide or amino acid sequences. It displays conserved positions, sequence differences and structural annotations from known sources.

Instructions
1. Select an alignment category

Select "Nucleotide sequences" or "Amino acid sequences". Use one category per task. After the first sequence is added, the other category cannot be selected. Delete all sequences or reset the list to choose again. The current category stays selected.

2. Add sequences

Select "Add sequence". Choose "Search database" or "Custom input".

Search database
  • Enter a gene name or NCBI ID. Select the gene by species, gene name and aliases.
  • Select a sequence type. Nucleotide input supports mRNA, CDS and pre-mRNA. Amino acid input uses the fixed protein type.
  • Select a transcript. The list shows its ID and source tags. "MANE" means MANE Select. "MANE Plus Clinical" identifies a supplementary clinical transcript.
  • For pre-mRNA, select the full sequence, one exon or one intron. Select only one region at a time.
  • Check the selected sequence and length. To check its source, select "View source in Sequence Viewer".
  • Select "Save".
Figure 1. Select a database sequence

Figure 1. Select a database sequence

Custom input
  • Paste one raw sequence or multiple FASTA records.
  • For multiple sequences, start each record with ">name". Wrapped sequence lines under one header are joined. Text without a header is treated as one sequence and named automatically.
  • Check the name, sequence, length and status in the preview. Correct all errors, then select "Save".
Figure 2. Custom input and validation preview

Figure 2. Custom input and validation preview

3. Start alignment

After adding 2–15 sequences, check the list. Select a record to edit it or use its delete button to remove it. Confirm the input, then select "Start". Results open in a new tab.

Input rules and limits

Prepare inputs as follows. Correct each error in its record. The tool preserves input and does not truncate sequences or discard excess records.

  • Count: Use 2–15 sequences per task. "Start" is disabled with fewer than 2 sequences. If a batch exceeds the remaining capacity, the whole batch stays in the dialog and the input is preserved. Reduce the count before adding it.
  • Length: Use at most 60,000 nt per nucleotide sequence or 20,000 aa per amino acid sequence.
  • Names: Use no more than 400 characters. Count each ASCII character as 1 and each other character as 2, up to a total of 400. Names must be unique; comparisons ignore case and surrounding whitespace.
  • Nucleotides: Use only A, T, C, G and N. U is accepted and converted to T.
  • Amino acids: Use only the 20 standard amino acid letters and X: A, C, D, E, F, G, H, I, K, L, M, N, P, Q, R, S, T, V, W, Y, X.
  • Stop markers: An amino acid sequence may end with a single *. Do not use * inside a sequence or multiple * characters at the end.
  • Formatting: Letters are uppercased. Spaces, tabs and line breaks are removed.
Interpret results

Each row in the alignment represents one sequence. Each column represents corresponding positions after alignment. Use the statistics and conservation symbols to assess sequence agreement and the distribution of differences.

Figure 3. Nucleotide pairwise alignment results

Figure 3. Nucleotide pairwise alignment results

Figure 4. Amino acid pairwise alignment results

Figure 4. Amino acid pairwise alignment results

1. Alignment statistics
MetricMeaning
IdentityThe number of columns with identical nucleotides or amino acids, divided by the total alignment length. A higher value means more positions are identical in this alignment.
SimilarityFor amino acid sequences only. The number of identical, strongly similar and weakly similar columns, divided by the total alignment length. It reflects agreement in sequence or physicochemical properties; it does not establish that the proteins have the same function.
GapsThe number of columns containing a gap, divided by the total alignment length. A gap, shown as −, is a placeholder introduced by the alignment algorithm, not a nucleotide or amino acid.

All three denominators include gap columns. For example, Identity of 54.24% (32 / 59) means that 32 of the 59 alignment positions are identical. Similarity includes Identity; do not add the two percentages.

These statistics apply to pairwise alignments. For multiple alignments, use the symbols below to interpret conservation at each column.

2. Conservation symbols and colours

Amino acids with different letters can still have similar physicochemical properties, such as hydrophobicity or charge. Clustal uses : and . to distinguish strong and weak similarity.

SymbolMeaningBackground colour
*Identical: all sequences have the same nucleotide or amino acid at this column.White
:Strong similarity: the amino acids are not all identical but belong to a common Clustal strong similarity group.Very pale purple
.Weak similarity: the column does not meet the strong similarity criteria but the amino acids belong to a common weak similarity group.Light purple
No symbolDifferent: the column meets none of the above criteria or contains a gap. This does not mean that every sequence differs from every other sequence at this column.Deeper purple
−Gap: a placeholder used for alignment. It may reflect insertion or deletion differences between sequences, but a gap alone does not establish which sequence underwent an insertion or deletion.Deeper purple

Strong and weak similarity apply only to amino acid sequences. Nucleotide alignments distinguish identical and different columns only. Columns containing gaps do not show *, : or .

3. UTR and CDS annotations
  • UTR (untranslated region): a region on either side of the mRNA coding region that does not encode amino acids, marked by a light green underline.
  • CDS (coding sequence): the nucleotide region involved in encoding a protein, marked by a dark green underline.

These marks come from structural annotations of known source sequences. They are independent of the conservation states shown by the background colours. UTR and CDS annotations are not inferred for custom sequences.

4. Position coordinates
  • Alignment position: the column number after alignment, including inserted gaps.
  • Sequence position: the position within the input sequence or selected fragment, numbered from 1 and excluding gaps.

For example, if the original sequence ACG is aligned as A−CG, C has alignment position 3 and sequence position 2. A gap has no corresponding sequence position and is shown as "—".

→Go to tool
CONTENTS
Overview
Instructions
1. Select an alignment category
2. Add sequences
Search database
Custom input
3. Start alignment
Input rules and limits
Interpret results
1. Alignment statistics
2. Conservation symbols and colours
3. UTR and CDS annotations
4. Position coordinates
Cyagen
Home
Tools
Database
Resources
About Us
Email: icyagen-support@cyagen.com
Phone: +86 18620792549
Address: No.98, Xiangxue Road, Huangpu District, Guangzhou City
Follow us on social media
Contact us via LinkedIn
Link: https://www.linkedin.com/company/cyagen-biosciences
Copy
Contact us via YouTube
Link: https://www.youtube.com/@Cyagen
Copy
iCyagen
Copyright © 2024 Cyagen Biosciences. All Rights Reserved.
Privacy Policy
User Agreement
Back to top